Two sets of chemical dosing system have been installed complete successfully

Two sets of chemical dosing systems which orderd by the company from Changzhou have been complete successfully.Our company designate technicists to the customer’s factory to help the workers to debug and install the chemical dosing systems.The customer satisfied with our professional services very much.The two sets chemical dosing system,one is used for air conditioning cooling water system,the other is used for air conditioning chilled water system.
The chemical dosing system which produced by PEIDE is widely used in central air-conditional recycle cooling water,chilled water(hot water for heating device),steam boiler,swimming pool,fire deluge system,ice slurry storage system,condensate,landscape water,rain collect system,reclaimed water system,sewage system and for the industrial process water in industry of steel,petrochemistry,thermal power,paper making,oil field,microelectronics,medicine.From design to installation ,debugging and after-sales are all made by PEIDE independently.Before the installation of chemical dosing system,it need to take the water sample to analyse,then to debug the chemical dosing system according to the water sample report.

The debugging and installation of chemical dosing system as below:

 

the installation of chemical dosing system2the installation of chemical dosing system3the installation of chemical dosing system4

the installation of chemical dosing system1

 

 

 

 

 

 

 

 

 

Central air conditioning cooling water continuously recycled in the system, the water temperature and flow rate are constantly changing. The cooling water evaporation and concentration of various inorganic substances will cause system’s accumulation of sediment,equipment corrosion and a large number of microbial bacteria and algae breeding, thus lead to serious clogging and corrosion of pipes and other problems.

The configuration table of chemical dosing system for air conditioning cooling water system(three tank with three pump)

 

Equipment Name Quantity
Metering pump2 units
Dosing tank2 pieces
Germicide metering pump1 unit
Germicide dosing tank1 unit
On-line monitoring for conductivity1 unit
On-line monitoring for PH1 unit
On-line monitoring for corrosion1 unit
Electromagnetic drain valve1 unit
Nonmetallic pressure gauge3 pieces
Damper3 pieces
Relief valve3 pieces
Filter1 piece
Pipe fitting and other accessories1 set
Control cabinet1 set
Low level protection3 sets
Flow-limiting valve1 set
Bracket1 set
Impulse flow meter1 set

 

Central air conditioning chilled water system water temperature in summer is during 7 ℃ -12 ℃. Cryogenic freezing water has a strong tendency to corrosion, control acid corrosion chilled water systems, dissolved oxygen corrosion and electrochemical corrosion are the major problems for water treatment.

 

The configuration table of chemical dosing system for air conditioning chilled water system(two tank with two pump)

 

Equipment NameQuantity
Corrosion inhabitor metering pump1 unit
Corrosion inhabitor dosing tank1 piece
Germicide metering pump1 unit
Germicide dosing tank1 unit
On-line monitoring for conductivity1 unit
On-line monitoring for PH1 unit
On-line monitoring for corrosion1 unit
Electromagnetic drain valve1 unit
Nonmetallic pressure gauge2 pieces
Damper2 pieces
Relief valve2 pieces
Metallic filter1 piece
Pipe fitting and other accessories1 set
Control cabinet1 set
Low level protection1 set
Flow-limiting valve1 set
Bracket1 set
Impulse flow meter1 set

 

If you want to get more information about the package of chemical dosing system and the operating instruction of chemical dosing system,please click here.

 

 

 

 

 